Our Products - List all
DSC PT10
The Differential Scanning Calorimeter DSC PT10 comprises the advantages of latest technology, highest resolution and a robust easy to use instrument design. Temperature range (-150 up to 700°C)
DSC PT1600
World class High Temperature Differential Scanning Calorimeter for the determination of caloric effects and specific heat (Cp) over a broad temperature range.
DTA PT1600 Differential Thermal Analysis
Differential Thermal Analysis is the most common thermal analysis method due to its wide range of information provided. The Linseis high temperature DTA - Differential Thermal Analyzer is desighned to deliver highest sensitivity, short time constants and a condensation free sample chamber. These features guarantee superior resolution, baseline stability over the entire instrument lifetime.
EGA - FTIR
Optimized FTIR coupling abilities with Linseis range of Thermal Analyzers, especially suitable for organics
EGA - Optical In-Situ Evolved Gas Analysis
Optimized QMS coupling abilities with Linseis Thermo balances, Dilatometers, Thermomechanical Analyzer or Differential Scanning Calorimeters
EGA - QMS
Optimized QMS coupling abilities with Linseis Thermo balances, Dilatometers, Thermomechanical Analyzer or Differential Scanning Calorimeters
HFM - Heat Flow Meter Thermal Conductivity Analyzer
The Linseis HFM - Heat Flow Meter provides a rapid and easy to use instrument to determine the thermal conductivity properties of low thermal conductivity insulation materials and other materials with a high level of accuracy.
more details on HFM - Heat Flow Meter Thermal Conductivity Analyzer
High Pressure HP-TGA-DSC
The High Pressure HP-TGA, simultaneous thermogravimetry (TGA) - differential scanning calorimetry (DSC) delivers unsurpassed performance. The system can be used to determine simultaneous changes of mass (TG) and caloric reactions (DSC) under defined atmosphere and pressure (up to 50 bar)
L75 / 120LT
The Linseis dilatometer L75/120LT was developed to measure the expansion of polymer samples. Hereby up to 8 different samples can be measured simultaneously in a temperature range of –40°C up to +160°C.
L75 / Laser
Unmatched resolution and absolute accuracy is possible with the Linseis Laser Dilatometer of the Pico-series. As the name indicates already the resolution goes up to Picometers (0,3nm = 300 Picometer). That means resolutions can be obtained which are up to a factor 33,33 higher as the resolution that were possible up to date.
